Users Guide
Command History
This guide is platform-specic. For command information about other platforms, see the relevant Dell
Networking OS Command Line Reference Guide.
Version Description
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
8.3.1.0 Introduced on the S-Series.
ethernet cfm
Spawn the CFM process. No CFM conguration is allowed until the CFM process is spawned.
Syntax
ethernet cfm
Defaults Disabled
Command Modes CONFIGURATION
Command History
This guide is platform-specic. For command information about other platforms, see the relevant Dell
Networking OS Command Line Reference Guide.
Version Description
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
8.3.1.0 Introduced on the S-Series.
ethernet cfm mep
Create an MEP.
Syntax
ethernet cfm mep {up-mep | down-mep} domain {name | level} ma-name name
mepid mep-id
Parameters
[up-mep | down-
mep]
Specify whether the MEP is up or down facing.
• Up-MEP: monitors the forwarding path internal to a bridge on the customer or
provider edge; on Dell Networking systems, the internal forwarding path is
eectively the switch fabric and forwarding engine.
802.1ag
169