Users Guide

Version Description
9.7(0.0) Introduced on the S6000-ON.
9.5(0.1) Introduced on the Z9500.
9.4(0.0) Introduced on the S4810, S4820T, S6000, and Z9000.
8.4.2.1 Introduced on the C-Series and S-Series.
8.4.2.0 Introduced on the E-Series.
7.5.1.0 Introduced on the E-Series.
redirect
Congure a rule for the redirect list.
S4810
Syntax
redirect {ip-address | slot/port} | tunnel tunnel-id}[track <obj-id>] {ip-
protocol-number | protocol-type [bit]} {source mask | any | host ip-
address} {destination mask | any | host ip-address} [operator]
To remove this lter, use one of the following:
Use the no seq sequence-number command if you know the lter’s sequence number.
You can also use the no redirect {ip-address | slot/port}| tunnel tunnel-id}
[track <obj-id>] {ip-protocol-number [bit] | protocol-type} {source mask
| any | host ip-address} {destination mask | any | host ip-address}
[operator] command.
Parameters
redirect Enter the keyword redirect to assign the sequence to the redirect list.
ip-address Enter the IP address of the forwarding router.
slot/port Enter the keyword slot / port followed by the slot/port information.
tunnel Enter the keyword tunnel to congure the tunnel setting.
tunnel-id Enter the keyword tunnel-id to redirect the trac.
track Enter the keyword track to enable the tracking.
track <obj-id> Enter the keyword track <obj-id> to track object-id.
ip-protocol-number Enter a number from 0 to 255 for the protocol identied in the IP protocol header.
protocol-type Enter one of the following keywords as the protocol type:
icmp for internet control message protocol
ip for any internet protocol
tcp for transmission control protocol
udp for user datagram protocol
bit (OPTIONAL) For the TCP protocol type only, enter one or a combination of the
following TCP ags:
1202
Policy-based Routing (PBR)