Reference Guide
600 | Interfaces
www.dell.com | support.dell.com
Parameters
Command Modes
EXEC
EXEC Privilege
Command
History
Usage
Information
Use this show interfaces command for details on a specific interface. Use the show interfaces
linecard
command for details on all interfaces on the designated line card.
On the S4810, the show interface output displays incorrect rate information details over time
for link monitoring when the rate-interval is configured for 5 seconds. Dell Force10
recommends using higher rate-intervals such as 15 to 299 seconds to minimize the errors
Note: In the CLI output, the power value will be rounded to a 3-digit value. For
receive/transmit power that is less than 0.000, an snmp query will return the
corresponding dbm value even though the CLI displays as 0.000.
interface
Enter one of the following keywords and slot/port or number information:
• For a Fast Ethernet interface, enter the keyword
FastEthernet followed by the
slot/port information.
• For a 1-Gigabit Ethernet interface, enter the keyword
GigabitEthernet followed
by the slot/port information.
• For a Loopback interface, enter the keyword
loopback followed by a number
from 0 to 16383.
• For the management interface on an RPM, enter the keyword
ManagementEthernet followed by the slot/port information. The slot range is 0
to 1 and the port range is 0.
• For a Null interface, enter the keywords
null 0.
• For a Port Channel interface, enter the keyword port-channel followed by a
number:
C-Series and S-Series Range: 1 to 128
E-Series Range: 1 to 255 for TeraScale and 1 to 512 for ExaScale.
• For a SONET interface, enter the keyword sonet followed by the slot/port.
• For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet
followed by the slot/port information.
• For a 40-Gigabit Ethernet interface, enter the keyword
fortyGigE followed by the
slot/port information.
• For a VLAN interface, enter the keyword vlan followed by a number from 1 to 4094.
Version 8.3.12.1 Updated command output to support multiple IPv6 addresses.
Version 8.5.1.0 Added support for 4-port 40G line cards on ExaScale.
Version 8.3.7.0 Introduced on S4810
Version 8.2.1.2 Include SFP and SFP+ optics power detail in E-Series and C-Series output.
Version 8.2.1.0 Support for 4093 VLANs on E-Series ExaScale. Prior releases supported 2094.
Version 8.1.1.0 Introduced on E-Series ExaScale
Version 7.8.1.0 Output expanded to include SFP+ media in C-Series
Version 7.6.1.0 Introduced on S-Series
Version 7.5.1.0 Introduced on C-Series
Version 6.4.1.0 Changed organization of display output
Version 6.3.1.0 Added Pluggable Media Type field in E-Series TeraScale output