Reference Guide

Uplink Failure Detection (UFD) | 1471
Related
Commands
show uplink-state-group
s S50 only
Display status information on a specified uplink-state group or all groups.
Syntax
show uplink-state-group [group-id] [detail]
Parameters
Defaults
None
Command Modes
EXEC
EXEC Privilege
Command
History
Example
FTOS# show uplink-state-group
Uplink State Group: 1 Status: Enabled, Up
Uplink State Group: 3 Status: Enabled, Up
Uplink State Group: 5 Status: Enabled, Down
Uplink State Group: 6 Status: Enabled, Up
Uplink State Group: 7 Status: Enabled, Up
Uplink State Group: 16 Status: Disabled, Up
FTOS# show uplink-state-group 16
Uplink State Group: 16 Status: Disabled, Up
FTOS#show uplink-state-group detail
(Up): Interface up (Dwn): Interface down (Dis): Interface disabled
Uplink State Group : 1 Status: Enabled, Up
Upstream Interfaces :
Downstream Interfaces :
Uplink State Group : 3 Status: Enabled, Up
Upstream Interfaces : Gi 0/46(Up) Gi 0/47(Up)
Downstream Interfaces : Te 13/0(Up) Te 13/1(Up) Te 13/3(Up) Te 13/5(Up) Te 13/6(Up)
Uplink State Group : 5 Status: Enabled, Down
Upstream Interfaces : Gi 0/0(Dwn) Gi 0/3(Dwn) Gi 0/5(Dwn)
show uplink-state-group Display status information on a specified uplink-state group or all
groups.
uplink-state-group Create an uplink-state group and enabling the tracking of upstream
links.
group-id Displays status information on a specified uplink-state group or all
groups. Valid group-id values are 1 to 16.
detail Displays additional status information on the upstream and
downstream interfaces in each group
Version 8.3.12.0 Introduced on S4810
Version 8.4.2.3 Introduced on the S-Series S50.