Reference Guide

Control and Monitoring | 139
Burned In MAC : 00:01:e8:cc:cc:cc
No Of MACs : 3
--Module 0--
Status : online
Module Type : S50-01-10GE-2P - 2-port 10GE XFP (SB)
Num Ports : 2
Hot Pluggable : no
-- Module 1 -
Status : online
Module Type : S50-01-10GE-2C - 2-port 10GE CX4 (SB)
Num Ports : 2
Hot Pluggable : no
- Power Supplies --
Unit Bay Status Type
---------------------------------------------------------------------------
0 0 up AC
0 1 absent
-- Fan Status --
------------------------------------------------------------------------------
Unit TrayStatus Fan0 Fan1 Fan2 Fan3 Fan4 Fan5
0 up up up up up up up
FTOS#
Related
Commands
show tech-support (C-Series and E-Series)
c e
Display, or save to a file, a collection of data from other show commands, the information
necessary for Force10 Networks technical support to perform troubleshooting.
Syntax
show tech-support [linecard 0-6 | page] | {display | except | find | grep | no-more | save}
Parameters
show version Display the FTOS version.
show processes memory
(S-Series)
Display memory usage based on running processes.
show system stack-ports Display information about the stack ports on all switches in the
S-Series stack.
show hardware stack-unit Display the data plane and management plane input and output
statistics of a particular stack member.
stack-unit priority Configure the ability of an S-Series switch to become the
management unit of a stack.
linecard 0-6 (OPTIONAL) Enter the keyword linecard followed by the linecard number to
view information relating to a specific linecard.
page
(OPTIONAL) Enter the keyword page to view 24 lines of text at a time.
Press the SPACE BAR to view the next 24 lines.
Press the ENTER key to view the next line of text.