Reference Guide
Simple Network Management Protocol and Syslog | 1375
If this command is not configured, no traps controlled by this command are sent. If you do not
specify a
notification-type and notification-option, all traps are enabled.
Related
Commands
snmp-server engineID
c e s z
Configure name for both the local and remote SNMP engines on the router.
Syntax
snmp-server engineID [local engineID] [remote ip-address udp-port port-number engineID]
To return to the default, use the
no snmp-server engineID [local engineID] [remote ip-address
udp-port port-number engineID] command
Parameters
Defaults
As above
Command Modes
CONFIGURATION
Command
History
Usage
Information
Changing the value of the SNMP Engine ID has important side effects. A user's password
(entered on the command line) is converted to an MD5 (Message Digest Algorithm) or SHA
(Secure Hash Algorithm) security digest. This digest is based on both the password and the
local Engine ID. The command line password is then destroyed, as required by RFC 2274.
Because of this deletion, if the local value of the Engine ID changes, the security digests of
SNMPv3 users will be invalid, and the users will have to be reconfigured.
For the remote Engine ID, the host IP and UDP port are the indexes to the command that are
matched to either overwrite or remove the configuration.
snmp-server
community
Enable SNMP and set the community string.
local engineID
Enter the keyword local followed by the engine ID number that
identifies the copy of the SNMP on the local device.
Format (as specified in RFC 3411): 12 octets.
• The first 4 octets are set to the private enterprise number.
• The remaining 8 octets are the MAC address of the chassis.
remote ip-address
Enter the keyword remote followed by the IP address that identifies
the copy of the SNMP on the remote device.
udp-port port-number
engineID
Enter the keyword udp-port followed by the UDP (User Datagram
Protocol) port number on the remote device.
Range: 0 to 65535
Default: 162
Version 8.3.11.1 Introduced on Z9000
Version 8.3.7.0 Introduced on S4810
Version 7.6.1.0 Support added for S-Series
Version 7.5.1.0 Support added for C-Series
E-Series legacy command