Reference Guide

418 | Interfaces
www.dell.com | support.dell.com
MTU is 1554 bytes
Inbound access list is not set
Proxy ARP is enabled
Split Horizon is enabled
Poison Reverse is disabled
ICMP redirects are not sent
ICMP unreachables are not sent
Management Interfaces
The S4810 system supports the Management Ethernet interface as well as the standard S-Series interface
on any port. Either method can be used to connect to the system.
Configure Management Interfaces on the E-Series, C-Series
and S4810
On the E-Series, C-Series, and S4810 the dedicated Management interface provides management access to
the system. You can configure this interface with FTOS, but the configuration options on this interface are
limited. Gateway addresses and IP addresses cannot be configured if it appears in the main routing table of
FTOS. In addition, Proxy ARP is not supported on this interface.
To configure a Management interface, use the following command in the CONFIGURATION mode:
To view the Primary RPM Management port, use the
show interface Managementethernet command in the
EXEC Privilege mode. If there are 2 RPMs, the you cannot view information on that interface.
Note: On the S4810, a default IP address is assigned to the Management port. Use this IP address to set
your laptop Ethernet port to the same network for test purposes.
Command Syntax Command Mode Purpose
interface Managementethernet interface
CONFIGURATION Enter the slot and the port (0).
ON the E-Series and C-Series, dual RPMs can
be in use.
Slot range:
C-Series, E-Series: 0-1
S4810: 0