Setup Guide

Optics installation
WARNING: When working with optical bers, follow all warning labels and always
wear eye protection. Never look directly into the end of a terminated or
unterminated ber or connector as it may cause eye damage.
1 Position the optic so it is in the correct position.
The optic has a key that prevents it from being inserted incorrectly.
2 Insert the optic into the port until it gently snaps into place.
NOTE: When you cable the ports, be sure not to interfere with the airow
from the small vent holes above and below the ports.
Switch power-up
Supply power to the S4200-ON Series (S4248FB-ON and S4248FBL-ON) switch after you
mount it in a rack or cabinet.
Reinspect your switch before power up. Verify the following:
The equipment is properly secured to the rack. Dell EMC recommends properly
grounding the switch.
The ambient temperature around the unit, which may be higher than the room
temperature, is within the limits specied for the S4200-ON Series, see Specications.
There is sucient airow around the unit.
The input circuits are correctly sized for the loads and that you use sucient overcurrent
protection devices.
All protective covers are in place.
Blank panels are installed if you do not install optional modules.
CAUTION
: Do not power up the switch if you did not install a fan module.
NOTE: A US AC power cable is included for powering up an AC power supply. You
must order all other power cables separately.
NOTE: ESD damage can occur if components are mishandled. Always wear an ESD-
preventive wrist or heel ground strap when handling the switch and its components.
S4200-ON Series Installation 23