Install Guide

Table 6. Environmental parameters (continued)
Parameter Specifications
NOTE: Reduce maximum temperature by 1°C/300 meters
(1°F/547 feet) above 950 meters (3,117 feet).
Operating humidity 5% to 85% (RH), non-condensing, continuously
5% to 90% (RH), non-condensing, short term
Short term is </= 1% of operational hours per year.
Storage temperature 40° to 70°C (40° to 158°F )
Storage humidity 5% to 95%, non-condensing
Maximum thermal output 600 W = 2047 BTU/Hr
Maximum operational altitude 10,000 feet (3,048 meters)
Maximum non-operational altitude 39,370 feet (12,000 meters)
Shock Dell EMC Spec SV0115
Table 7. AC power requirements
Parameter Specifications
Power supply 100240 VAC 50/60 Hz
Maximum current draw per system 6A/5A at 100/120V AC 3A/2.5A at 200/240V AC
Maximum power consumption 600 Watts
Typical power consumption 300 Watts
Table 8. DC power requirements
Parameter Specifications
Minimum and maximum input voltage range 40.5, 60V DC, 15A Max
Maximum power consumption 600 Watts
Start up VDC 39.0 ± 1.5 V
Start off VDC 37.5 ± 1.5 v
IEEE standards
The S4200-ON Series (S4248FB-ON and S4248FBL-ON) switch complies with the following IEEE standards:
802.1ab (LLDP)
802.1ax (Layer 2)
802.1d, 802.1w, 802.1s, 802.1x (Mgmt/Security), 802.3x (Layer 2)
802.3 (1000BASE-KX)
802.3ba (40GbE and 100GbE ports)
42