Deployment Guide
29 ScaleIO/VxFlex OS IP Fabric Best Practice and Deployment Guide with OS10EE | version 1.0
i. On the first host in the cluster, select the appropriate vmnic (vmnic0 in this example) and
click .
ii. Select lag1-0 > OK.
iii. On the same host, select the next appropriate vmnic (vmnic5 in this example) and click
.
iv. Select lag1-1 > OK.
v. On the same host, select the next appropriate vmnic (vmnic1 in this example) and click
.
vi. Select lag2-0 > OK.
vii. On the same host, select the next appropriate vmnic (vmnic4 in this example) and click
.
viii. Select lag2-1 > OK.
ix. Repeat steps i – viii for the remaining hosts in the cluster.
x. Click Next when done.
e. On the Analyze impact page, Overall impact status should indicate .
f. Click Next > Finish.
When complete, the Configure > Settings > Topology page for the VDS should look similar to Figure 21: