Deployment Guide
Table Of Contents
- 1 Introduction
- 2 Hardware overview
- 3 Topology overview
- 4 Preparation
- 5 S4148U-ON switch configuration
- 6 S4148U-ON validation
- 7 Configure Unity FC storage
- 8 Configure storage on ESXi hosts
- 9 Configure ESXi hosts for LAN traffic
- A Validated components
- B Technical support and resources
- C Support and feedback
37 Dell EMC Networking FCoE-to-Fibre Channel Deployment with S4148U-ON in F_port Mode | version 1.0
18:66:da:71:50:ad Eth 1/1/31 e4:f0:04:6b:05:41 ~ 1002
0e:fc:64:64:7c:00 64:7c:00 20:01:18:66:da:71:50:ad 20:00:18:66:da:71:50:ad
18:66:da:77:d0:c3 Eth 1/1/32 e4:f0:04:6b:05:41 ~ 1002
0e:fc:64:64:80:00 64:80:00 20:01:18:66:da:77:d0:c3 20:00:18:66:da:77:d0:c3
6.2.5 show vfabric
The show vfabric command output provides a variety of information including the default zone mode, the
active zone set, and interfaces that are members of the vfabric.
S4148U-Leaf1# show vfabric
Fabric Name
Fabric Type FPORT
Fabric Id 100
Vlan Id 1002
FC-MAP 0xEFC64
Vlan priority 3
FCF Priority 128
FKA-Adv-Period Enabled,8
Config-State ACTIVE
Oper-State UP
==========================================
Switch Config Parameters
==========================================
Domain ID 100
==========================================
Switch Zoning Parameters
==========================================
Default Zone Mode: Deny
Active ZoneSet: zoneset1
==========================================
Members
fibrechannel1/1/1
fibrechannel1/1/3
ethernet1/1/31
ethernet1/1/32
==========================================
Note: By default, the Default Zone Mode is set to Deny. This setting denies access between FC nodes
except those in the same zone of the active zone set. To allow access between FC nodes in the absence of
an active zone set, change the Default Zone Mode to Allow with the following command sequence:
S4148U-Leaf1# configure terminal
S4148U-Leaf1(config)# vfabric vfabric_number
S4148U-Leaf1(conf-vfabric-100)# zone default-zone permit