Deployment Guide

Table Of Contents
35 Dell EMC Networking FCoE-to-Fibre Channel Deployment with S4148U-ON in F_port Mode | version 1.0
6.2.2 show fc ns switch
The show fc ns switch command shows all device ports logged into the fabric. In this deployment, four
ports are logged in to each switch: two storage ports and two CNA ports.
S4148U-Leaf1# show fc ns switch
Total number of devices = 4
Switch Name 10:00:e4:f0:04:6b:04:42
Domain Id 100
Switch Port fibrechannel1/1/1
FC-Id 64:04:00
Port Name 50:06:01:6e:47:e0:1b:19
Node Name 50:06:01:60:c7:e0:1b:19
Class of Service 8
Symbolic Port Name UNITY::::SPB10::FC::::::
Symbolic Node Name UNITY::::SPA::FC::::::
Port Type N_PORT
Registered with NameServer Yes
Registered for SCN Yes
Switch Name 10:00:e4:f0:04:6b:04:42
Domain Id 100
Switch Port fibrechannel1/1/3
FC-Id 64:0c:00
Port Name 50:06:01:66:47:e0:1b:19
Node Name 50:06:01:60:c7:e0:1b:19
Class of Service 8
Symbolic Port Name UNITY::::SPA10::FC::::::
Symbolic Node Name UNITY::::SPA::FC::::::
Port Type N_PORT
Registered with NameServer Yes
Registered for SCN Yes
Switch Name 10:00:e4:f0:04:6b:04:42
Domain Id 100
Switch Port ethernet1/1/31
FC-Id 64:7c:00
Port Name 20:01:18:66:da:71:50:ad
Node Name 20:00:18:66:da:71:50:ad
Class of Service 8
Symbolic Port Name QLogic 57800 bnx2fc v1.713.30.v60.6 over vmnic4
Symbolic Node Name QLogic 57800 bnx2fc v1.713.30.v60.6 over vmnic4
Port Type N_PORT
Registered with NameServer Yes
Registered for SCN Yes