Deployment Guide

Table Of Contents
34 Dell EMC Networking FCoE-to-Fibre Channel Deployment with S4148U-ON in F_port Mode | version 1.0
6.1.3 show vlt domain_id
VLT configuration is verified by running the show vlt domain_id command on each of the S4148U-ON
switches. The VLTi is shown as port channel 1000, and the link status is up. The role of one switch in the VLT
pair is primary and its peer switch (not shown) is assigned to the secondary role.
S4148U-Leaf1# show vlt 127
Domain ID : 127
Unit ID : 1
Role : primary
Version : 1.0
Local System MAC address : e4:f0:04:6b:04:42
VLT MAC address : e4:f0:04:6b:04:42
IP address : fda5:74c8:b79e:1::1
Delay-Restore timer : 90 seconds
Peer-Routing : Enabled
Peer-Routing-Timeout timer : 0 seconds
VLTi Link Status
port-channel1000 : up
VLT Peer Unit ID System MAC Address Status IP Address Version
-----------------------------------------------------------------------------
2 e4:f0:04:6b:01:42 up fda5:74c8:b79e:1::2 1.0
6.1.4 show vlt domain_id backup link
The show vlt domain_id backup link command verifies the VLT backup link is functional on the OOB
management network.
S4148U-Leaf1# show vlt 127 backup-link
VLT Backup Link
------------------------
Destination : 100.67.169.30
Peer Heartbeat status : Up
6.2 FC commands
6.2.1 show fc switch
The show fc switch command verifies the switch is in F_Port mode for FC traffic.
S4148U-Leaf1# show fc switch
Switch Mode : FPORT
Switch WWN : 10:00:e4:f0:04:6b:04:42