Deployment Guide
Table Of Contents
- 1 Introduction
- 2 Hardware overview
- 3 Topology overview
- 4 Preparation
- 5 S4148U-ON switch configuration
- 6 S4148U-ON validation
- 7 Configure Unity FC storage
- 8 Configure storage on ESXi hosts
- 9 Configure ESXi hosts for LAN traffic
- A Validated components
- B Technical support and resources
- C Support and feedback
17 Dell EMC Networking FCoE-to-Fibre Channel Deployment with S4148U-ON in F_port Mode | version 1.0
MAC address and FCoE WWPN for CNA port 1
5. Record the MAC Address and WWPN, outlined in red above. A convenient method is to copy and
paste these values into a text file.
Note: While the WWPN is used in the actual switch configuration for FC zoning, the MAC address is
recorded to identify the corresponding vmnic number in VMware.
6. Repeat steps 4 and 5 for the FCoE partition on port 2.
7. Repeat steps 1-6 for remaining servers.
The FCoE WWPNs and MAC addresses used in this deployment example are shown in Table 1. The Switch
column has been added for reference per the cable connections in the SAN topology diagram (Figure 8).
Server CNA FCoE port WWPNs and MACs
Server
Port
Switch
WWPN
MAC
R640-1
1
S4148U-Leaf1
20:01:18:66:DA:71:50:AD
18:66:DA:71:50:AC
R640-1
2
S4148U-Leaf2
20:01:18:66:DA:71:50:AF
18:66:DA:71:50:AE
R640-2
1
S4148U-Leaf1
20:01:18:66:DA:77:D0:C3
18:66:DA:77:D0:C2
R640-2
2
S4148U-Leaf2
20:01:18:66:DA:77:D0:C5
18:66:DA:77:D0:C4