15 Dell EMC Networking FCoE-to-Fibre Channel Deployment with S4148U-ON in F_port Mode | version 1.0
a. Set NIC Mode to Disabled.
b. Set iSCSI Offload Mode to Disabled.
c. Set FCoE Mode to Enabled, shown in Figure 11, and click Back.
CNA partition 2 configuration
10. If present, select Partition 3 Configuration. Set NIC, iSCSI and FCoE modes to Disabled and click
Back.
11. If present, select Partition 4 Configuration. Set NIC, iSCSI and FCoE modes to Disabled and click
Back.
12. Click Back > Finish.
13. When prompted, answer Yes to save changes and click OK in the Success window.
14. Select the second CNA port and repeat steps 6-13 above for port 2.
15. Click Finish > Finish and answer Yes to exit and reboot.
Repeat on remaining servers as needed.