Deployment Guide
28 Dell EMC Networking FCoE Deployment with S4148U-ON in NPG Mode
Two WWNs are listed for each port. The World Wide Node Name (WWNN), outlined in black, identifies this
Unity storage array (the node). It is not used in zone configuration. The WWPNs, outlined in blue, identify the
individual ports and are used for FC zoning.
3. Record the WWPNs as shown in Table 8. The Switch column has been added based on the physical
cable connections shown in Figure 6.
Storage array FC adapter WWPNs
Service
processor
Port Switch WWPN
SP A
0
6510-1 FC
50:06:01:66:47:E0:1B:19
SP A
1
6510-2 FC
50:06:01:67:47:E0:1B:19
SP B
0
6510-1 FC
50:06:01:6E:47:E0:1B:19
SP B
1
6510-2 FC
50:06:01:6F:47:E0:1B:19
B.2.1 Create a storage pool
1. Connect to the Unisphere GUI in a web browser and log in.
2. In the left pane under STORAGE, select Pools.
3. Click the icon. In the Create Pool dialog box, provide a Name and click Next.
4. Select appropriate storage tiers and RAID configuration for the pool. Click Next.
5. Under Select Amount of Storage, select the number of drives section. The total number of drives
and the total capacity will be displayed next to Totals. Click Next.
6. The Capability Profile Name section is optional. Click Next.
7. Review selections on the Summary page and click Finish to create the pool. Once the Overall
status shows 100%, click Close.
8. The pool is displayed on the STORAGE > Pools page as shown in Figure 12.
Storage pool created
B.2.2 Add ESXi hosts
1. In the Unisphere left pane under ACCESS, select VMware.
2. On the vCenters tab, click the icon to open the Add vCenter dialog box.
3. Enter the Network Name or Address of the vCenter server. Enter the vCenter User Name and
Password and click Find.