Deployment Guide

17 Dell EMC Networking FCoE Deployment with S4148U-ON in NPG Mode
S4148U-Leaf1
S4148U-Leaf2
interface vlan 1615
vrrp-group 15
virtual-address 172.16.15.254
interface vlan 1616
vrrp-group 16
virtual-address 172.16.16.254
interface vlan 1615
vrrp-group 15
virtual-address 172.16.15.254
interface vlan 1616
vrrp-group 16
virtual-address 172.16.16.254
Configure server-facing interfaces
S4148U-Leaf1
S4148U-Leaf2
interface ethernet 1/1/31
description "Server 1"
switchport mode trunk
switchport trunk allowed vlan 1612-
1616
spanning-tree port type edge
mtu 9216
no shutdown
interface ethernet 1/1/32
description "Server 2"
switchport mode trunk
switchport trunk allowed vlan 1612-
1616
spanning-tree port type edge
mtu 9216
no shutdown
interface ethernet 1/1/33
description "Server 3"
switchport mode trunk
switchport trunk allowed vlan 1612-
1616
spanning-tree port type edge
mtu 9216
no shutdown
interface ethernet 1/1/34
description "Server 4"
switchport mode trunk
switchport trunk allowed vlan 1612-
1616
spanning-tree port type edge
mtu 9216
no shutdown
interface ethernet 1/1/31
description "Server 1"
switchport mode trunk
switchport trunk allowed vlan 1612-
1616
spanning-tree port type edge
mtu 9216
no shutdown
interface ethernet 1/1/32
description "Server 2"
switchport mode trunk
switchport trunk allowed vlan 1612-
1616
spanning-tree port type edge
mtu 9216
no shutdown
interface ethernet 1/1/33
description "Server 3"
switchport mode trunk
switchport trunk allowed vlan 1612-
1616
spanning-tree port type edge
mtu 9216
no shutdown
interface ethernet 1/1/34
description "Server 4"
switchport mode trunk
switchport trunk allowed vlan 1612-
1616
spanning-tree port type edge
mtu 9216
no shutdown