Deployment Guide
16 Dell EMC Networking FCoE Deployment with S4148U-ON in NPG Mode
Configure the compute VLAN interfaces
The VLANs shown in this example represent a generic converged or hyper-converged deployment and
should be changed to apply to the deployment specifications.
S4148U-Leaf1
S4148U-Leaf2
interface Vlan 1612
ip address 172.16.12.1/24
description "vMotion"
no shutdown
interface Vlan 1613
ip address 172.16.13.1/24
description "vSAN"
no shutdown
interface Vlan 1614
ip address 172.16.14.1/24
description "web"
no shutdown
interface Vlan 1615
ip address 172.16.15.1/24
description "app"
no shutdown
interface Vlan 1616
ip address 172.16.16.1/24
description "db"
no shutdown
interface Vlan 1612
ip address 172.16.12.2/24
description "vMotion"
no shutdown
interface Vlan 1613
ip address 172.16.13.2/24
description "vSAN"
no shutdown
interface Vlan 1614
ip address 172.16.14.2/24
description "web"
no shutdown
interface Vlan 1615
ip address 172.16.15.2/24
description "app"
no shutdown
interface Vlan 1616
ip address 172.16.16.2/24
description "db"
no shutdown
Configure VRRP
VRRP is an active/standby first-hop redundancy protocol. When used among VLT peers, it becomes
active/active. Both VLT peers have the VRRP virtual MAC address in their forwarding table as a local
destination address. This allows the backup VRRP router to forward intercepted frames whose destination
MAC address matches the VRRP virtual MAC address.
S4148U-Leaf1
S4148U-Leaf2
vrrp version 3
interface vlan 1612
vrrp-group 12
virtual-address 172.16.12.254
interface vlan 1613
vrrp-group 13
virtual-address 172.16.13.254
interface vlan 1614
vrrp-group 14
virtual-address 172.16.14.254
vrrp version 3
interface vlan 1612
vrrp-group 12
virtual-address 172.16.12.254
interface vlan 1613
vrrp-group 13
virtual-address 172.16.13.254
interface vlan 1614
vrrp-group 14
virtual-address 172.16.14.254