15 Dell EMC Networking FCoE Deployment with S4148U-ON in NPG Mode
Configure the FC VLAN and virtual fabrics
For each switch define the VLANs and virtual fabrics. Apply to appropriate FC and server interfaces. The
global command feature fc npg puts the switch in NPG mode.
S4148U-Leaf1
S4148U-Leaf2
feature fc npg
interface vlan 1001
vfabric 101
vlan 1001
fcoe fcmap 0xEFC64
interface fibrechannel 1/1/1
no shutdown
vfabric 101
interface fibrechannel 1/1/3
no shutdown
vfabric 101
interface ethernet 1/1/31
vfabric 101
interface ethernet 1/1/32
vfabric 101
interface ethernet 1/1/33
vfabric 101
interface ethernet 1/1/34
vfabric 101
feature fc npg
interface vlan 1002
vfabric 102
vlan 1002
fcoe fcmap 0xEFC65
interface fibrechannel 1/1/1
no shutdown
vfabric 102
interface fibrechannel 1/1/3
no shutdown
vfabric 102
interface ethernet 1/1/31
vfabric 102
interface ethernet 1/1/32
vfabric 102
interface ethernet 1/1/33
vfabric 102
interface ethernet 1/1/34
vfabric 102
Note: The FCoE VLAN and FCoE map are used internally by the switch to forward FC traffic, even if FCoE is
not used by nodes connected to the switch.
The bulk of the FC portion of the configuration is now complete.
The following steps complete the configuration example by configuring common features found in a layer 3
leaf-spine network. For more information on leaf-spine networks see
Dell EMC Networking Layer 3 Leaf-