White Papers
S4148-ON Configuration Details
7 Dell EMC Networking – Deploying Native FC and FCoE on single S4148U-ON | 1.0
h. Switch(config-pmap-c-que)# end
i. Switch#
11. Configure the service policy maps and qos maps on all the relevant interfaces expected to receive LAN
and SAN traffic. In this case, there is only one interface that is expected to receive LAN and FCoE traffic.
a. Switch# conf t
b. Switch(config)# int eth1/1/53
c. Switch(config-eth1/1/53)# description Link_2_CNA_FCoE
d. Switch(config-eth1/1/53)# switchport mode trunk
e. Switch(config-eth1/1/53)# switchport access vlan 1
f. Switch(config-eth1/1/53)# service-policy input type network-qos PFC
g. Switch(config-eth1/1/53)# service-policy output type queuing ETS
h. Switch(config-eth1/1/53)# ets mode on
i. Switch(config-eth1/1/53)# qos-map traffic-class TC-Q
j. Switch(config-eth1/1/53)# priority-flow-control mode on
k. Switch(config-eth1/1/53)# vfabric 2
l. Switch(config-eth1/1/53)# spanning-tree port type edge
The configurations provided apply only to the Dell EMC S4148U switch. The CNA still needs to be properly
configured in order to bring up FCoE services. The setup in figure 1, uses ESXi 6.5 on the server with the CNA
adapter.