Deployment Guide
20 Dell EMC Networking Fibre Channel Deployment with S4148U-ON in F_port Mode | version 1.0
Note: If changes are subsequently made to aliases, zones, or zone sets, the zone set must be reactivated
for the changes to take effect. This is done with the following command sequence:
S4148U-Leaf1# configure terminal
S4148U-Leaf1(config)# vfabric vfabric_number
S4148U-Leaf1(conf-vfabric-100)# zoneset activate zoneset_name
Put enough unified ports in 16Gb FC mode for connections to the FC storage array. In this deployment
example, four FC ports per S4148U-ON switch are used. In switch port profile-3, unified port groups 1 and 2
(entered as 1/1/1 and 1/1/2) provide two 16Gb FC interfaces each.
Note: For more information on mapping ports to switch profiles and port groups, see OS10 Enterprise
Edition User Guide Release 10.4.0E(R3), p.83-85.
Add the server and storage Fibre Channel interfaces to vfabric 100.
Finally, exit configuration mode and save the configuration with the end and write memory commands.
S4148U-Leaf1
S4148U-Leaf2
port-group 1/1/1
mode fc 16g-2x
port-group 1/1/2
mode fc 16g-2x
interface fibrechannel 1/1/1
description "To SPB"
no shutdown
vfabric 100
interface fibrechannel 1/1/3
description "To SPA"
no shutdown
vfabric 100
interface fibrechannel 1/1/5
description "To Server 1"
no shutdown
vfabric 100
interface fibrechannel 1/1/7
description "To Server 2"
no shutdown
vfabric 100
end
write memory
port-group 1/1/1
mode fc 16g-2x
port-group 1/1/2
mode fc 16g-2x
interface fibrechannel 1/1/1
description "To SPB"
no shutdown
vfabric 100
interface fibrechannel 1/1/3
description "To SPA"
no shutdown
vfabric 100
interface fibrechannel 1/1/5
description "To Server 1"
no shutdown
vfabric 100
interface fibrechannel 1/1/7
description "To Server 2"
no shutdown
vfabric 100
end
write memory