Reference Guide

ipv6 address autoconfig
!
support-assist
!
policy-map type application policy-iscsi
!
class-map type application class-iscsi
!
class-map type qos class-trust
Supported Releases 10.2.0E or later
show system
Displays system information.
Syntax
show system [brief | node-id]
Parameters
brief — View abbreviated list of system information.
node-id — Node ID number.
Default Not congured
Command Mode EXEC
Usage Information None
Example
OS10# show system
Node Id : 1
MAC : 90:b1:1c:f4:aa:b2
Number of MACs : 129
Up Time : 23:43:10
-- Unit 1 --
Status : up
System Identifier : 1
Down Reason : user-triggered
System Location LED : off
Required Type : S6000
Current Type : S6000
Hardware Revision : A01
Software Version : 10.2.9999E
Physical Ports : 32x40GbE
BIOS : 3.33.0.2
System CPLD : 0.3
Master CPLD : 0.4
Slave CPLD : 0.2
-- Power Supplies --
PSU-ID Status Type AirFlow Fan Speed(rpm) Status
----------------------------------------------------------------
1 up AC NORMAL 1 6688 up
2 fail
-- Fan Status --
FanTray Status AirFlow Fan Speed(rpm) Status
----------------------------------------------------------------
1 up NORMAL 1 7201 up
2 6874 up
60