Reference Guide
1 3ffe:501:ffff:100:201:e8ff:fe00:4c8b
000.000 ms 000.000 ms 000.000 ms
View diagnostics
View system diagnostic information using show commands. The show hash-algorithm command is used to view the current hash
algorithms conīgured for LAG and ECMP.
View environment
OS10# show environment
Unit State Temperature Voltage
--------------------------------------------
1 up 36
--------------------------------------------
Thermal sensors
Unit Sensor-Id Sensor-name Temperature
--------------------------------------------------
1 1 T2 temp sensor 26
1 2 system-NIC temp sensor 22
1 3 Ambient temp sensor 22
1 4 NPU temp sensor 38
-------------------------------------------------
View hash algorithm
OS10# show hash-algorithm
LagAlgo - CRC EcmpAlgo - CRC
View inventory
OS10# show inventory
--------------------------------------------
System Inventory
--------------------------------------------
Unit : 1
Current model : S6000
Provisioned model: S6000
Software version : 10.0.0P.1965
Vendor : DELL
Product : S6000-ON
Hw version : A02
Platform : x86_64-dell_s6000_s1220-r0
PPID : CN07VJDK2829852R0032
Service-tag : 5XYK0Z1
------------- Power Supplies -----------------
----------------------------------------------
PSU-ID AirFlow PPID
----------------------------------------------
1 NORMAL CN0T9FNW2829852R026
2 NORMAL CN0T9FNW2829852R026
-------------- Fantrays ----------------------
----------------------------------------------
FanTray-ID AirFlow PPID
----------------------------------------------
1 NORMAL CN0MGDH82829852R039
2 NORMAL CN0MGDH82829852R039
3 NORMAL CN0MGDH82829852R039
Troubleshoot OS10
587