Setup Guide

Parameter Specications
Storage temperature –40° to 158°F (–40° to 70°C).
Storage and nonoperating humidity 5 to 95 percent (RH), noncondensing.
Maximum thermal output 1568 BTH/hr.
Maximum operational altitude 10,000 feet (3,048 meters).
Maximum nonoperational altitude No performance degradation to 35,000 feet
(10,668 meters).
Shock Meets Bellcore Zone 4 earthquake
requirements (MIL-STD-810).
Table 4. AC power requirements
Parameter Specications
Power Supply 100–240 VAC 50/60 Hz.
Maximum current draw per system
4.6 A @ 460 watts/100vac.
2.3 A @ 460 watts/200vac.
Maximum Power Consumption 460 Watts.
Typical Power Consumption 338 Watts.
Table 5. DC power requirements
Parameter Specications
Minimum/maximum input voltage range -40.5V/ -48V/ -60V
Input power at full load
−40.5V/970W −48V/930W −60V/ 950W
(without fan).
−40.5V/980W −48V/940W −60V/ 960W
(with fan).
Input current at full load
−40.5V/23.8A −48V/19.0A −60V/ 15.6A
(without fan).
Technical specications 33