Install Guide

LED Description
Blinking amber—noncritical system error—fan failure or power
supply failure
Power
Solid green—normal
Solid amber—POST is in progress
Blinking amber—power supply failed
O—no power
Fan
Solid green—fan powered and running at the expected RPM
Blinking amber—fan failed, including incompatible airow
direction when you insert the PSU or fan trays with diering
airows
Locator
O—locator function is disabled
Blinking blue—locator function is enabled
QSFP+ port when used as one 40G port—only rst LED is used in
40G mode
O—No Link
Solid green—link at 40G speed
Blinking green—port activity at 40G speed
Solid amber—link at speed lower than 40G
Blinking amber—port activity at lower than 40G speed
Blinking amber one second on/one second o—port locator
function
QSFP+ port when used as four ports of 10G—all four LEDs are
used
O—no Link
Solid amber4x10G speed
Blinking amber—port activity at 4x10G speed
Blinking amber one second on/one second o—port locator
function
Stack ID Number
Displays the stack unit number of the switch
Displays 1 by default if switch is not part of a stack
Figure 5. S4048T-ON PSU-side LEDs
1 Fan LED
The S4048T-ON System
9