Install Guide
LED Description
• Blinking amber—noncritical system error—fan failure or power
supply failure
Power
• Solid green—normal
• Solid amber—POST is in progress
• Blinking amber—power supply failed
• O—no power
Fan
• Solid green—fan powered and running at the expected RPM
• Blinking amber—fan failed, including incompatible airow
direction when you insert the PSU or fan trays with diering
airows
Locator
• O—locator function is disabled
• Blinking blue—locator function is enabled
QSFP+ port when used as one 40G port—only rst LED is used in
40G mode
• O—No Link
• Solid green—link at 40G speed
• Blinking green—port activity at 40G speed
• Solid amber—link at speed lower than 40G
• Blinking amber—port activity at lower than 40G speed
• Blinking amber one second on/one second o—port locator
function
QSFP+ port when used as four ports of 10G—all four LEDs are
used
• O—no Link
• Solid amber—4x10G speed
• Blinking amber—port activity at 4x10G speed
• Blinking amber one second on/one second o—port locator
function
Stack ID Number
Displays the stack unit number of the switch
Displays 1 by default if switch is not part of a stack
Figure 5. S4048T-ON PSU-side LEDs
1 Fan LED
The S4048T-ON System
9