Install Guide
Power supplies
The S4048T-ON ships with two power supply units.
The system supports AC or DC power supplies with two air-ow directions—from the I/O side to the PSU side and from the PSU side to
the I/O side. Two PSUs are required for full redundancy, but the system can operate with a single PSU.
The PSUs are eld replaceable. When running with full redundancy—two power supply units installed and running, you can remove and
replace one PSU without disrupting trac.
NOTE: If you use a single PSU, install a blank plate in the other PSU slot. Dell EMC recommends using PSU2 as the blank plate
slot.
NOTE: Connect the power supply to the appropriate branch circuit protection as dened by your local electrical codes. Verify
that the remote power source complies with the switch input power specications.
NOTE: ESD damage can occur if components are mishandled. Always wear an ESD-preventive wrist or heel ground strap when
handling the S4048T-ON and its components.
CAUTION: To prevent electrical shock, verify that the S4048T-ON is grounded properly. If you do not ground your equipment
correctly, excessive emissions may result. Use a qualied electrician to ensure that the power cables meet your local electrical
requirements.
Topics:
• Components
• AC power supply installation
• DC power supply connection
Components
The following power supply options are available for the S4048T-ON:
• AC or DC power supply with integrated fan
• AC or DC power supply with integrated reverse ow fan
PSU1 is on the left side of the chassis; PSU2 is on the right side of the chassis.
Figure 16. S4048T-ON PSU-side view
1
PSU1 2 Fan modules
6
30 Power supplies