Test uplink_prbs_ext_test for NPU 0 ............ SKIPPED <<<---
NPU tests ...................................... Passed
CPU Traffic with Adjacent Loopback
Tests the traffic sent from the CPU internally generated packet to the front-end ports which are connected with direct attach
cables (DACs) or optics with cables connected top-to-bottom.
Connect all the ports with DACs or 40G/100G optics with cables.
• nputool -i -t 1 -T cpu_adj
• nputool --init --test 1 --traffic cpu_adj
root@amazon:/opt/ngos/bin# ./nputool -i -t 1 -T cpu_adj
DMA pool size: 67108864
PCI unit 0: Dev 0xb960, Rev 0x01, Chip BCM56960_A0, Driver BCM56960_A0
sysconf_probe successful
global_sal_config successful
*** 1 BCM devices are detected
Current mode is now ESW
Diag NPU initialization over
Test link_status_test for NPU 0 ............ SKIPPED <<<---
Test snake_traffic_test for NPU 0 .......... Passed
Test prbs_mac_test for NPU 0 ............... SKIPPED <<<---
Test prbs_ext_test for NPU 0 ............... SKIPPED <<<---
Test uplink_link_status_test for NPU 0 ..... SKIPPED <<<---
Test uplink_snake_traffic_test for NPU 0 ... SKIPPED <<<---
Test uplink_prbs_mac_test for NPU 0 ........ SKIPPED <<<---
Test uplink_prbs_ext_test for NPU 0 ........ SKIPPED <<<---
NPU tests .................................. Passed
root@dell-diag-os:/opt/ngos/bin#
root@amazon:/opt/ngos/bin# ./nputool --init -test 1 --traffic cpu_adj
DMA pool size: 67108864
PCI unit 0: Dev 0xb960, Rev 0x01, Chip BCM56960_A0, Driver BCM56960_A0
sysconf_probe successful
global_sal_config successful
*** 1 BCM devices are detected
Current mode is now ESW
Diag NPU initialization over
Test link_status_test for NPU 0 ............... SKIPPED <<<---
Test snake_traffic_test for NPU 0 ............. Passed
Test prbs_mac_test for NPU 0 .................. SKIPPED <<<---
Test prbs_ext_test for NPU 0 .................. SKIPPED <<<---
Test uplink_link_status_test for NPU 0 ........ SKIPPED <<<---
Test uplink_snake_traffic_test for NPU 0 ...... SKIPPED <<<---
Test uplink_prbs_mac_test for NPU 0 ........... SKIPPED <<<---
Test uplink_prbs_ext_test for NPU 0 ........... SKIPPED <<<---
NPU tests ..................................... Passed
IXIA Traffic with External Loopback
Tests the traffic sent from IXIA to port-1 and to the front-end ports which are connected with external Loopback optics.
Connect the first port to IXIA and all other ports with QSFP28 Loopback optics.
• nputool -i -t 1 -T ixia_self -d
• nputool --init --test 1 --traffic ixia_self -d
These commands configure the virtual local area network (VLAN) and after the BCM.0> shell displays, send the traffic from IXIA.
To verify the counters, run the show c command in the BCM shell.
IXIA Traffic with Adjacent Loopback
Tests the traffic sent from IXIA to the front-end ports which are connected with DACs or optics with cables connected top-to-
bottom.
Dell DiagOS Tools 56