Administrator Guide

mac-address-table station-move threshold
Change the frequency with which the MAC address station-move trap is sent after a MAC address changes in a VLAN. A trap is sent if a
station move is detected above a threshold number of times in a given interval.
Syntax
[no] mac-address-table station-move threshold number interval count
Parameters
threshold
number
Enter the keyword threshold then the number of times MAC addresses in VLANs can
change before an SNMP trap is sent. The range is from 1 to 10.
interval
seconds
Enter the keyword interval then the number of seconds. The range is from 5 to 60.
Defaults Not configured.
Command Modes CONFIGURATION
Command History
This guide is platform-specific. For command information about other platforms, see the relevant Dell Networking
OS Command Line Reference Guide.
Version Description
9.8(0.0) Introduced on the S3048-ON and S4048-ON.
8.3.19.0 Introduced on the S4820T.
8.3.7.0 Introduced on the S4810.
7.5.1.0 Introduced on the C-Series.
pre-6.2.1.1 Introduced on the E-Series.
Usage Information For information about the specific trap sent and the corresponding Syslog, see SNMP Traps.
mac-address-table station-move refresh-arp
Ensure that address resolution protocol (ARP) refreshes the egress interface when a station move occurs due to a topology change.
Syntax
mac-address-table station-move refresh-arp
To disable the ARP refresh feature, use the no mac-address-table station-move refresh-arp
command.
Defaults Enabled
Command Modes CONFIGURATION
Command History
This guide is platform-specific. For command information about other platforms, see the relevant Dell EMC
Networking OS Command Line Reference Guide.
Version Description
9.10(0.1) Introduced on the S6010-ON and S4048T-ON.
9.10(0.0) Introduced on the S3148.
9.10(0.0) Introduced on the S6100–ON.
9.9(0.0) Modified the default option from none to Enabled.
9.8(2.0) Introduced on the S3100 series.
9.8(1.0) Introduced on the Z9100–ON.
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.7(0.0) Introduced on the S6000-ON.
9.2(1.0) Introduced on the Z9500.
926 Layer 2