Administrator Guide
Example —
System reboot
due to power loss
or pressing the
power button off
and on.
The example shows that the last system reboot was due to warm reset.
DellEMC#show reset-reason
Cause : Warm Reset
Reset Time : N/A.
Example —
System reboot
due to watchdog
timeout
DellEMC#show reset-reason
Cause: Watchdog timeout.
Reset Time: N/A
Example —
System reboot
due to thermal
shutdown
The example shows that the last system reboot was due to thermal shutdown.
DellEMC#show reset-reason
Cause: Thermal Shutdown.
Reset Time: N/A.
Example —
System reboot
due to BIOS boot
fail
The example shows the reason for the last reboot was due to BIOS boot fail.
DellEMC#show reset-reason
Cause: Reset on Boot Ok Fail.
Reset Time: N/A.
Example —
Unknown reason
If the reason for the last system reboot is not available, the system displays the reason as N/A.
DellEMC# show reload-reason
Cause: N/A
Time: N/A
Example — Reset
reason of a single
stack unit
DellEMC# show reset-reason stack-unit 1
Cause : Reset by User through CLI command
Reset Time: 11/05/2017-08:36
Example — Reset
reason of all stack
units
DellEMC#show reset-reason stack-unit all
Last Reset Reason:
---------------------
Type Cause Time
-----------------------------------------------------------------------------------
stack-unit 1 Reboot by Software 11/05/2017-09:04
stack-unit 2 Reboot by Software 11/05/2017-09:04
stack-unit 3 Cold Reset N/A
stack-unit 4 N/A N/A
stack-unit 5 N/A N/A
stack-unit 6 N/A N/A
show software ifm
Display interface management (IFM) data.
Syntax
show software ifm {clients [summary] | ifagt number | ifcb interface | stack-
unit unit-ID | trace-flags}
Parameters
clients Enter the keyword clients to display IFM client information.
summary (OPTIONAL) Enter the keyword summary to display brief information about IFM clients.
ifagt
number
Enter the keyword ifagt then the number of an interface agent to display software pipe
and IPC statistics.
ifcb
interface
Enter the keyword ifcb then one of the following interface IDs then the interface
information to display interface control block information for that interface:
Control and Monitoring 145