Users Guide
count number Enter the number of times a process can restart within the
configured period. The range is from 1 to 3. The default is 3.
period minutes Enter the amount of time within which the process can restart
count times. The range is from 1 to 60 minutes. The default is 60
minutes.
Default By default, a process can be restarted a maximum of three times within one hour. On
the exception that exceeds this limit, the system reloads or fails over.
Command Modes CONFIGURATION
Command History
This guide is platform-specific. For command information about other platforms, see
the relevant Dell Networking OS Command Line Reference Guide.
Version Description
9.10(0.1) Introduced on the S6010-ON and S4048T-ON.
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
8.3.19.0 Introduced on the S4820T.
8.3.12.0 Introduced on the S4810.
8.4.1.0 Introduced on the E-Series.
Related
Commands
• show processes restartable — display processes and tasks configured for
restartability.
redundancy auto-failover-limit
Specify an auto-failover limit for RPMs. When a non-recoverable fatal error is detected, an automatic RPM
failover occurs. This command does not affect user-initiated (manual) failovers.
Syntax
redundancy auto-failover-limit [count number [period minutes] |
period minutes]]
To disable the auto-failover limit control, use the no redundancy auto-failover-
limit command.
High Availability (HA) 805