Users Guide
Version Description
9.10(0.1) Introduced on the S6010-ON and S4048T-ON.
9.8(1.0) Introduced on the Z9100–ON.
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.7(0.0) Introduced the support for bmp-boot on the S-Series and Z-
Series switches.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
Usage Information To display these changes in the show bootvar command output, save the running
configuration to the startup configuration (using the copy command) and reload
system.
Use the bmp-boot keyword only when the device boots up from bare metal
provisioning (BMP). For an industrial standard upgraded device, the Dell networking OS
stores the image partition upgraded from the DHCP offer in the bmp-boot option.
cd
Change to a different working directory.
Syntax
cd [flash: | usbflash:] <directory name and path>
Parameters
flash: Use the keyword flash: to change the current directory to
internal flash and its sub directories.
usbflash: Use the keyword usbflash: to change the current directory to
the inserted USB.
directory name
and path
Enter the directory name and path as follows: directory name
([[flash://]directory_path])
NOTE: The cd command without any arguments will change the current
directory to flash:
Command Modes EXEC Privilege
Command History
This guide is platform-specific. For command information about other platforms, see
the relevant Dell Networking OS Command Line Reference Guide.
File Management 68