Users Guide
Usage Information
Resetting the management unit is not allowed, and an error message displays if you try
to do so. Resetting is a soft reboot, including flushing the forwarding tables.
Starting with Dell Networking OS version 7.8.1.0, you can run this command directly on
the stack standby unit (standby master) to reset the standby. You cannot reset any
other unit from the standby unit.
Example
Dell#reset stack-unit 4
Dell#00:15:00: %STKUNIT1-M:CP %CHMGR-5-STACKUNIT_RESET: stack-
unit 4 being reset
00:15:01: %STKUNIT1-M:CP %CHMGR-2-STACKUNIT_DOWN: stack-unit 4
down - reset
00:15:01: %STKUNIT1-M:CP %IFMGR-1-DEL_PORT: Removed port: Te
4/1-4/48, Fo 4/51-4/52,
00:15:01: %STKUNIT2-S:CP %IFMGR-1-DEL_PORT: Removed port: Te
4/1-4/48, Fo 4/51-4/52,
Dell#00:15:08: %S4048-ON:1 %IFAGT-5-STACK_PORT_LINK_DOWN: Changed
stack port state to down: 1/49
00:15:08: %STKUNIT1-M:CP %CHMGR-2-STACKUNIT_DOWN: stack-unit 4
down - card removed
Dell#
Related
Commands
• reload – reboots Dell Networking OS.
mixed-mode-stacking
Enables the mixed-mode stacking feature on the S4048T-ON and the S4048–ON. This feature allows a
S4048-ON to join a S4048T-ON stack. Similarly, this feature also allows a S4048T–ON to join a S4048–ON
stack.
S4048–ON S4048T-ON
Syntax
mixed-mode-stacking enable
To remove the current stack group configuration, use the no mixed-mode-stacking
enable command.
Parameters
enable Enter the keyword enable to enable mixed-mode stacking on
the switch.
Defaults Disabled
Command Modes
• CONFIGURATION
Stacking 1915