Users Guide

Version Description
9.0.2.0 Introduced on the S6000.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
8.2.1.0 Introduced on S-Series Stacking.
8.1.1.0 Introduced on the E-Series.
7.7.1.0 Introduced on the S-Series.
7.6.1.0 Introduced on the C-Series.
6.2.1.1 Introduced on the E-Series.
Usage Information This command changes the sampling rate for an interface. By default, the sampling rate
of an interface is set to the same value as the current global default sampling rate. If the
value entered is not a correct power of 2, the command generates an error message
with the previous and next power-of-2 value. Select one of these two number and re-
enter the command.
Related
Commands
sflow sample-rate (Global) — changes the sampling rate globally.
show sflow
Display the current sFlow configuration.
Syntax
show sflow [interface]
Parameters
interface (OPTIONAL) Enter the following keywords and slot/port or
number information:
For a 10-Gigabit Ethernet interface, enter the keyword
TenGigabitEthernet then the slot/port[/subport]
information.
For a 40-Gigabit Ethernet interface, enter the keyword
fortyGigE then the slot/port information.
For a Loopback interface, enter the keyword loopback
then a number from 0 to 16383.
For the Management interface on the, enter the keyword
ManagementEthernet then the slot/port information.
For a port-channel interface, enter the keywords port-
channel then the port-channel ID.
sFlow 1847