Users Guide

rising-threshold
value event-
number
Enter the keywords rising-threshold then the value (64 bit)
the rising-threshold alarm is either triggered or reset. Then enter
the event-number to trigger when the rising threshold exceeds
its limit. This value is the same as the alarmRisingEventIndex or
alarmTable of the RMON MIB. If there is no corresponding
rising-threshold event, the value is zero.
falling-threshold
value event-
number
Enter the keywords falling-threshold then the value (64 bit)
the falling-threshold alarm is either triggered or reset. Then
enter the event-number to trigger when the falling threshold
exceeds its limit. This value is the same as the
alarmFallingEventIndex or the alarmTable of the RMON MIB. If
there is no corresponding falling-threshold event, the value is
zero.
owner string (OPTIONAL) Enter the keyword owner then the owner name to
specify an owner for the alarm. This is the alarmOwner object in
the alarmTable of the RMON MIB.
Defaults owner
Command Modes CONFIGURATION
Command History
This guide is platform-specific. For command information about other platforms, see
the relevant Dell Networking OS Command Line Reference Guide.
Version Description
9.10(0.1) Introduced on the S6010-ON and S4048T-ON.
9.8(1.0) Introduced on the Z9100-ON.
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.7(0.0) Introduced on the S6000-ON.
9.2(1.0) Introduced on the Z9500.
9.0.2.0 Introduced on the S6000.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
7.6.1.0 Introduced on the S-Series.
7.5.1.0 Introduced on the C-Series.
6.1.1.0 Introduced on the E-Series.
Remote Monitoring (RMON) 1686