Users Guide
show running-cong ecmp-group
Display interfaces, LAG, or LAG link bundles being monitored for uneven trac distribution using the ecmp-group monitoring
enable command. The ECMP group could have a LAG or a list of interfaces (not just LAG link-bundles).
Syntax
show running-config ecmp-group
Defaults Disabled.
Command Modes CONFIGURATION
Command History
This guide is platform-specic. For command information about other platforms, see the relevant Dell EMC
Networking OS Command Line Reference Guide.
Version Description
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.7(0.0) Introduced on the S6000-ON.
9.2(1.0) Introduced on the Z9500.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.10.0 Introduced on the S4810.
Related Commands
• ecmp-group — congure a mechanism to monitor trac distribution.
show system stack-unit fanout congured
Displays the details about the fanned-out ports.
Syntax
show system stack-unit stack-unit-number fanout configured
Parameters
stack-unit stack-
unit-number
The stack Unit ID of the device.
fanout congured Enter the keywords fanout configured to display the details about the fanned-out
ports.
Defaults None.
Command Modes
• EXEC
• EXEC Privilege
Command History
This guide is platform-specic. For command information about other platforms, see the relevant Dell EMC
Networking OS Command Line Reference Guide.
Interfaces 833