Users Guide

ipv6 route bfd
Enable BFD for all IPv6 neighbors congured through static routes.
Syntax
ipv6 route bfd [vrf vrf-name] [prefix-list prefix-list-name] [interval interval
min_rx min_rx multiplier value role {active | passive}]
To disable BFD for all IPv6 neighbors congured through static routes, use the no ipv6 route bfd [vrf
vrf-name] [prefix-list prefix-list-name] [interval interval min_rx min_rx
multiplier value role {active | passive}] command.
Parameters
vrf vrf-name (Optional) Enter the keyword vrf and then the name of the VRF to enable or disable
BFD on the next-hop IPv6 neighbor corresponding to that VRF.
prex-list prex-list-
name
(Optional) Enter the keyword prefix-list followed by the name of the prex list to
enable or disable BFD on specic IPv6 neighbors.
interval milliseconds (OPTIONAL) Enter the keywords interval to specify non-default BFD session
parameters beginning with the transmission interval. The range is from 50 to 1000. The
default is 200.
min_rx milliseconds Enter the keywords min_rx to specify the minimum rate at which the local system
receives control packets from the remote system. The range is from 50 to 1000. The
default is 200.
multiplier value Enter the keywords multiplier to specify the number of packets that must be missed
in order to declare a session down. The range is from 3 to 50. The default is 3.
role [active |
passive]
Enter the role that the local system assumes:
Active — active system initiates the BFD session. Both systems can be active for
the same session.
Passive — passive system does not initiate a session. It only responds to a request
for session initialization from the active system.
The default is Active.
Defaults See Parameters.
Command Modes CONFIGURATION
Command History
This guide is platform-specic. For command information about other platforms, see the relevant Dell EMC
Networking OS Command Line Reference Guide.
Version Description
9.13(0.0) Introduced on the S3100 series, S3048–ON, S4048–ON, S4048T-ON, S5000, S6000,
S6000–ON, S6100–ON, C9010, and the Z9500.
9.12(1.0) Introduced on the S5048F–ON.
9.11(2.5) Introduced the ipv6 route bfd command on the Z9100–ON.
Example
DellEMC(conf)#ipv6 route bfd
DellEMC(conf)#ipv6 route bfd vrf vrf1 prefix-list p6_le
382 Bidirectional Forwarding Detection (BFD)