Users Guide

unmounting /usr/pkg (/dev/wd0i)...
unmounting /boot (/dev/wd0b)...
unmounting /usr (mfs:29)...
unmounting /force10 (mfs:24)...
unmounting /lib (mfs:21)...
unmounting /f10 (mfs:18)...
unmounting /tmp (mfs:9)...
unmounting /kern (kernfs)...
unmounting / (/dev/md0a)... done
rebooting...
Dell#conf t
Dell(conf)#no mixed-mode-stacking enable
Disabling Mixed-mode stacking requires a config save and reload to operate
back as S4048T.
Do you want to reload? Proceed[confirm yes/no]:yes
System configuration has been modified. Save? [yes/no]: yes
!
Apr 10 19:19:18: %STKUNIT2-M:CP %FILEMGR-5-FILESAVED: Copied running-config to
startup-config in flash by default
Apr 10 19:19:18: %STKUNIT2-M:CP %CHMGR-5-RELOAD: User request to reload the
chassis
syncing disks... done
unmounting file systems...
unmounting /f10/flash (/dev/wd0e)...
unmounting /f10/ConfD/db (mfs:479)...
unmounting /usr/pkg (/dev/wd0i)...
unmounting /boot (/dev/wd0b)...
unmounting /usr (mfs:29)...
unmounting /force10 (mfs:24)...
unmounting /lib (mfs:21)...
unmounting /f10 (mfs:18)...
unmounting /tmp (mfs:9)...
unmounting /kern (kernfs)...
unmounting / (/dev/md0a)... done
rebooting...
Example (S4048–
ON)
Dell#conf t
Dell(conf)#mixed-mode-stacking enable
Dell#conf t
Dell(conf)#no mixed-mode-stacking enable
redundancy disable-auto-reboot
Prevent the S-Series stack management unit, stack member unit, and standby unit from rebooting if they fail.
Syntax
redundancy disable-auto-reboot stack-unit [1–6 | members]
To return to the default, use the no redundancy disable-auto-reboot stack-unit command.
Parameters
stack-unit Enter the stack-unit number. The range is from 1 to 6.
members Enter the keyword members for all stack-units.
Defaults Disabled (the failed switch is automatically rebooted).
1802 Stacking