Users Guide
Command Modes
• CONFIGURATION
Command History
This guide is platform-specic. For command information about other platforms, see the relevant Dell Networking
OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.10(0.1) Introduced on the S4048T-ON and S4048–ON.
Usage Information
• To form a mixed-mode stack, use only the 40G ports between the range 49 to 54.
• You cannot form a mixed-mode stack using the 10G ports. Because, the 10G ports on the S4048T are copper
ports; where as, the 10G ports on the S4048-ON are SFP ports.
• It is mandatory to enable mixed-mode stacking on the S4048-ON and S4048T-ON switches before joining a
mixed-mode stack.
• Stack election is based on the priority or the MAC address of the stack units as in homogenous stacking. The
stack-unit with the highest priority or MAC address is chosen as the master.
• TDR is a feature that is supported only on the S4048T-ON but not on the S4048-ON. If TDR is congured on
the S4048T-ON, then mixed-mode stacking can be enabled only on the S4048T-ON switches.
• The hardware watchdog command is enabled only when the S4048T-ON act as master. As a single image
runs on both the S4048T-ON as well as the S4048–ON, the hardware watchdog command is retained on
the S4048-ON also. However, this command remains ineective and does not perform any function when the
S4048-ON acts as master.
• When the S4048T-ON is the master and mixed-mode stacking is disabled, the S4048-ON remains in the card
problem state due to type mismatch.
• When the S4048-ON is the master and mixed-mode stacking is disabled, the S4048T-ON remains in the card
problem state due to type mismatch.
After you issue this command. the following message appears prompting you to conrm the conguration:
Enabling mixed-mode-stacking requires configuration save and reload to operate
in compatible with S4048-ON. Do you want to reload? Proceed[confirm yes/no]:
To make the S4048T-ON work like the S4048–ON, enter yes at this prompt and press the return key. The
following message appears prompting you to save the conguration:
System configuration has been modified. Save? [yes/no]:
Enter yes again and press the return key.
Example (S4048T-
ON)
Dell#conf t
Dell(conf)#mixed-mode-stacking enable
Enabling Mixed-mode stacking requires config save and reload to operate in
Compatible to S4048.
Do you want to reload? Proceed[confirm yes/no]:yes
System configuration has been modified. Save? [yes/no]: yes
!
Apr 10 19:16:38: %STKUNIT2-M:CP %FILEMGR-5-FILESAVED: Copied running-config to
startup-config in flash by default
Apr 10 19:16:39: %STKUNIT2-M:CP %CHMGR-5-RELOAD: User request to reload the
chassis
syncing disks... 4 1 done
unmounting file systems...
unmounting /f10/flash (/dev/wd0e)...
unmounting /f10/ConfD/db (mfs:479)...
Stacking 1801