Users Guide
• If no BPDU is received from a remote device, loop guard places the port in a Loop-Inconsistent Blocking state
and no trac is forwarded on the port.
Example
DellEMC(conf)# interface tengigabitethernet 4/1
DellEMC(conf-if-gi-4/0)# spanning-tree rstp edge-port
DellEMC(conf-if-gi-4/0)# show config
!
interface TenGigabitEthernet 4/1
no ip address
switchport
spanning-tree rstp edge-port
no shutdown
DellEMC#
tc-ush-standard
Enable the MAC address ushing after receiving every topology change notication.
Syntax
tc-flush-standard
To disable, use the no tc-flush-standard command.
Defaults Disabled
Command Modes CONFIGURATION (conf-rstp)
Command History
This guide is platform-specic. For command information about other platforms, see the relevant Dell EMC
Networking OS Command Line Reference Guide.
Version Description
9.10(0.1) Introduced on the S6010-ON and S4048T-ON.
9.10(0.0) Introduced on the S3148.
9.10(0.0) Introduced on the S6100-ON.
9.8(2.0) Introduced on the S3100 series.
9.8(1.0) Introduced on the Z9100-ON.
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.7(0.0) Introduced on the S6000-ON.
9.2(1.0) Introduced on the Z9500.
9.0.2.0 Introduced on the S6000.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
7.6.1.0 Introduced on the S-Series.
7.5.1.0 Introduced on the C-Series.
6.5.1.0 Introduced on the E-Series.
Rapid Spanning Tree Protocol (RSTP) 1583