Setup Guide

Specications
This chapter lists the S4048–ON specications.
CAUTION: Operate the product at an ambient temperature not higher than 113°F (45°C).
CAUTION: Lithium Battery Caution: There is a danger of explosion if the battery is incorrectly replaced. Replace only with same
or equivalent type of battery. Dispose of the batteries according to the manufacturer's instructions.
Topics:
Chassis physical design
IEEE standards
Agency compliance
Network Equipment Building Systems Compliance
USA Federal Communications Commission Statement
European Union EMC Directive Conformance Statement
Japan VCCI Compliance for Class A Equipment
Korean Certication of Compliance
Safety Standards and Compliance Agency Certications
Electromagnetic Compatibility
Product recycling and disposal
Chassis physical design
Table 6. Chassis physical design
Parameter Specications
Height 1.71 inches (43.5 mm)
Width 17.09 inches (434 mm)
Depth 18.11 inches (460 mm)
Chassis weight with factory-installed components 21.7 lbs (9.86 kg)
Rack clearance required
Front: 5 inches (12.7 cm)
Rear: 5 inches (12.7 cm)
Table 7. Environmental parameters
Parameter Specications
Operating temperature 32° to 113°F (0° to 45°C)
Operating humidity 5 to 85% (RH), non-condensing
Storage temperature –40° to 158°F (–40° to 70°C)