Setup Guide

Power supplies
The S4048–ON ships with one AC power supply. Dell EMC recommends purchasing a second power supply.
The S4048–ON supports AC power supplies with two air-ow directions, normal and reverse. Normal is from the I/O-side to the PSU-side.
Reverse is from the PSU-side to the I/O-side. Two PSUs are required for full redundancy, but the switch can operate with a single PSU.
The PSUs are eld replaceable. When running with full redundancy—two power supplies installed and running, you can remove and replace
one PSU without disrupting trac.
NOTE: If you use a single PSU, install a blank plate in the other PSU slot. Dell EMC recommends using power supply 2 (PSU2) as
the blank plate slot.
NOTE: ESD damage can occur if components are mishandled. Always wear an ESD-preventive wrist or heel ground strap when
handling the S4048–ON and its components.
CAUTION: To prevent electrical shock, ensure that the S4048-ON is grounded properly. If you do not ground your equipment
correctly, excessive emissions may result. Use a qualied electrician to ensure that the power cables meet your local electrical
requirements.
Topics:
Components
AC power supply installation
DC power supply installation
Components
The following power supply options are available for the S4048–ON.
AC power supply with integrated fan
AC power supply with integrated reverse ow fan
Power supply 1 (PSU1) is on the left side of the chassis; power supply 2 (PSU2) is on the right side of the chassis.
Figure 12. S4048–ON power supply units (PSUs)
1 PSU 1
2 PSU 2
6
Power supplies 25