Service Manual
Usage
Information
The patch filename includes the Dell Networking OS version, the platform, the CPU, and the process it
affects (FTOS-platform-cpu-process-patchversion.rtp). For example, a patch labeled
“7.8.1.0-EH-rp2-l2mgr-1.rtp” identifies that this patch applies to Dell Networking OS version 7.8.1.0 — E-
Series platform, for RP2, addressing the layer 2 management process, and this patch is the first version
of this patch.
There is no need to reload or reboot the system when you insert the patch. The In-Service Modular patch
replaces the existing process code. After installation is complete, the system executes the patch code as
though it was always there.
Related
Commands
show patch — displays the system patches loaded with the in-service modular hot fix
command.
process restartable
Enable a process to be restarted. Restartability is subject to a maximum restart limit. This limit is defined as a configured number
of restarts within a configured amount of time. On the software exception that exceeds the limit, the system reloads (for
systems with a single RPM) or fails over (for systems with dual RPMs).
Syntax
process restartable [process] [count number] [period minutes]
Parameters
process
Configure a process to be restartable.
count
number
Enter the number of times a process can restart within the configured period. The
range is from 1 to 3. The default is 3.
period
minutes
Enter the amount of time within which the process can restart count times. The
range is from 1 to 60 minutes. The default is 60 minutes.
Default By default, a process can be restarted a maximum of three times within one hour. On the exception that
exceeds this limit, the system reloads or fails over.
Command Modes CONFIGURATION
Command
History
This guide is platform-specific. For command information about other platforms, refer to the relevant Dell
Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
8.3.19.0 Introduced on the S4820T.
8.3.12.0 Introduced on the S4810.
8.4.1.0 Introduced on the E-Series.
Related
Commands
show processes restartable
redundancy auto-failover-limit
Specify an auto-failover limit for RPMs. When a non-recoverable fatal error is detected, an automatic RPM failover occurs. This
command does not affect user-initiated (manual) failovers.
Syntax
redundancy auto-failover-limit [count number [period minutes] | period
minutes]]
High Availability (HA) 589