Administrator Guide
Usage Information This command is found on the Management interface only.
Related
Commands
• interface ManagementEthernet — configure the Management port on the system (either the Primary or
Standby RPM).
• management route — configure a static route that points to the Management interface or a forwarding
router.
stack-unit portmode quad
Configures the list of dynamic fan-out capable ports.
Syntax
stack-unit [stack-unit number] port port-number portmode quad
To remove the quad-port configuration, use the command.
Parameters
stack-unit number
Enter the port number. The range is from 1 to 6.
Defaults 49,50,51,52,53,54
Command Modes CONFIGURATION
Command History
Version Description
9.10(0.1) Introduced on the S6010-ON and S4048T-ON.
9.8(0.0P5) Introduced on the S4048-ON.
9.7(0.0) Introduced on the S6000 and S6000–ON.
Usage Information
For the new quad port profile configuration to take effect, you must first save changes and then reload the
switch.
Example
Dell(conf)#stack-unit 1 port 49 portmode quad
Warning: Enabling Quad mode on stack-unit 1 port 49. Please verify whether
the configs related to interface Fo 1/49 are cleaned up before proceeding
further.
[confirm yes/no]:yes
Quad mode is enabled on stack-unit 1 port 49
Dell(conf)#Jan 1 13:37:01: %STKUNIT1-M:CP %IFMGR-5-DYNAMIC_FANOUT: Port 49
in slot 1 has been fanned-out
TenGigabitEthernet 1/49/1 unassigned NO Manual administratively
down down
TenGigabitEthernet 1/49/2 unassigned NO Manual administratively
down down
TenGigabitEthernet 1/49/3 unassigned NO Manual administratively
down down
TenGigabitEthernet 1/49/4 unassigned NO Manual administratively
down down
switchport
Place an interface in Layer 2 mode.
Syntax
switchport [[backup interface {interface | port-channel number}] | mode
private-vlan {host | promisucous | trunk}]
To remove an interface from Layer 2 mode and place it in Layer 3 mode, enter the no switchport command.
If a switchport backup interface is configured, first remove the backup configuration. To remove a switchport
backup interface, enter the no switchport backup interface command.
Parameters
backup (OPTIONAL) Use this option to configure a redundant Layer 2 link without using Spanning
Tree. The keyword backup configures a backup port so that if the primary port fails, the
backup port changes to the up state. If the primary later comes up, it becomes the
backup.
722 Interfaces