Administrator Guide

Line Description
RS state This is the reserved digital state of the pin AS(1) per SFF-8079 and RS(1) per SFF-8431.
Tx Disable state If the admin status of the port is down then this flag is set to true.
Temperature High
Alarm Flag
This can be either true or false, depending on the Current voltage value displayed above.
Voltage High
Alarm Flag
This can be either true or false, depending on the Current Temperature value displayed
above.
Tx Bias High Alarm
Flag
This can be either true or false, depending on the present Tx bias current value displayed
above.
Tx Power High
Alarm Flag
This can be either true or false, depending on the Current Tx bias power value displayed
above.
Rx Power High
Alarm Flag
This can be either true or false, depending on the Current Rx power value displayed
above.
Temperature Low
Alarm Flag
This can be either true or false, depending on the Current Temperature value displayed
above.
Voltage Low Alarm
Flag
This can be either true or false, depending on the Current voltage value displayed above.
Tx Bias Low Alarm
Flag
This can be either true or false, depending on the Tx bias current value displayed above.
Tx Power Low
Alarm Flag
This can be either true or false, depending on the Current Tx power value displayed
above.
Rx Power Low
Alarm Flag
This can be either true or false, depending on the Current Rx power value displayed
above.
Temperature High
Warning Flag
This can be either true or false, depending on the Current Temperature value displayed
above.
Voltage High
Warning Flag
This can be either true or false, depending on the Current Voltage value displayed above.
Tx Bias High
Warning Flag
This can be either true or false, depending on the Tx bias current value displayed above.
Tx Power High
Warning Flag
This can be either true or false, depending on the Current Tx power value displayed
above.
Rx Power High
Warning Flag
This can be either true or false, depending on the Current Tx power value displayed
above.
Temperature Low
Warning Flag
This can be either true or false, depending on the Current Temperature value displayed
above.
Voltage Low
Warning Flag
This can be either true or false, depending on the Current Voltage value displayed above.
Tx Bias Low
Warning Flag
This can be either true or false, depending on the present Tx bias current value displayed
above.
Tx Power Low
Warning Flag
This can be either true or false, depending on the Current Tx power value displayed
above.
Rx Power Low
Warning Flag
This can be either true or false, depending on the Current Rx power value displayed
above.
Example
DellEMC# show interfaces TengigabitEthernet 1/1 transceiver
SFP is present.
SFP 0 Serial Base ID fields
SFP 0 Id = 0x03
SFP 0 Ext Id = 0x04
SFP 0 Connector = 0x07
714 Interfaces