Service Manual

Table Of Contents
Dell# show environment fan
-- Fan Status --
Unit Bay TrayStatus Fan0 Speed Fan1 Speed
----------------------------------------------------
0 0 up up 7021 up 7021
0 1 up up 6971 up 7072
0 2 up up 7021 up 6971
Speed in RPM
Dell#show environment pem
-- Power Supplies --
Unit Bay Status Type FanStatus FanSpeed(rpm)
------------------------------------------------------------
0 0 down UNKNOWN down 0
0 1 up AC up 6504
Dell#show environment thermal-sensor
-- Thermal Sensor Readings (deg C) --
Unit Sensor0 Sensor1 Sensor2 Sensor3 Sensor4 Sensor5 Sensor6
-------------------------------------------------------------------
0 39 36 37 37 31 31 46
show inventory
Display the switch type, components (including media), and Dell Networking Operating System (OS), including hardware
identification numbers and configured protocols.
Syntax
show inventory [media slot]
Parameters
media
slot
(OPTIONAL) Enter the keyword media then the stack ID of the stack member for which
you want to display pluggable media inventory.
NOTE: This parameter is available but not supported in Dell Networking Operating
System version 8.3.11.4. Because stacking is not supported, if you use this
parameter, the output displays β€œMedia not present or accessible” (refer to the Usage
Information section).
Defaults none
Command Modes CONFIGURATION
Command
History
This guide is platform-specific. For command information about other platforms, see the relevant Dell
Networking OS Command Line Reference Guide.
Version Description
9.8(1.0) Introduced on the Z9100–ON.
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.7(0.0) Introduced on the S6000-ON.
9.2(1.0) Introduced on the Z9500.
9.0.2.0 Introduced on the S6000.
9.0.0.0 Introduced on the Z9000.
8.3.19.0 Introduced on the S4820T.
8.3.12.0 Introduced on the S4810.
8.3.11.4 Output expanded to include Piece Part ID (PPID) and eSR4 optics.
Control and Monitoring 123