Service Manual

seq ether-type (for Extended MAC ACLs)
Configure an egress filter with a specific sequence number that filters traffic with specified types of
Ethernet packets. This command is supported only on 12-port GE line cards with SFP optics. For
specifications, refer to your line card documentation.
NOTE: Only the options that have been newly introduced in Release 9.3(0.0) and Release 9.4(0.0)
are described here. For a complete description on all of the keywords and variables that are
available with this command, refer the topic of this command discussed earlier in this guide.
Syntax
seq sequence-number {deny | permit} ether-type protocol-type-
number {destination-mac-address mac-address-mask | any} vlan
vlan-id {source-mac-address mac-address-mask | any} [count
[byte]] [order] [log [interval minutes] [threshold-in-msgs
[count]] [monitor]
To remove this filter, use the no seq sequence-number command.
Parameters
log (OPTIONAL) Enter the keyword log to enable the triggering
of ACL log messages.
threshold-in msgs
count
(OPTIONAL) Enter the threshold-in-msgs keyword
followed by a value to indicate the maximum number of
ACL logs that can be generated, exceeding which the
generation of ACL logs is terminated. with the seq, permit,
or deny commands. You can enter a threshold in the range
of 1-100.
interval minutes (OPTIONAL) Enter the keyword interval followed by the
time period in minutes at which ACL logs must be
generated. You can enter an interval in the range of 1-10
minutes.
monitor (OPTIONAL) Enter the keyword monitor when the rule is
describing the traffic that you want to monitor and the ACL
in which you are creating the rule is applied to the
monitored interface.
Defaults
By default, 10 ACL logs are generated if you do not specify the threshold explicitly.
The default frequency at which ACL logs are generated is 5 minutes. By default,
flow-based monitoring is not enabled.
Command Modes CONFIGURATION-EXTENDED-ACCESS-LIST
Command History
Version Description
9.7(0.0) Introduced on the S6000–ON.
9.4(0.0) Added support for flow-based monitoring on the S4810,
S4820T, S6000, Z9000, and MXL 10/40GbE Switch IO
Module platforms.
Access Control Lists (ACL)
355