Service Manual

Version Description
8.3.7.0 Introduced on the S4810.
8.2.1.0 Introduced on the C-Series, E-Series TeraScale, and E-
Series ExaScale. Maximum rate limit on E-Series reduced
from 4000 to 3000.
7.4.1.0 Introduced
Example
Dell(conf-if-vl-2)#vlan-stack compatible
Dell(conf-if-vl-2-stack)#protocol-tunnle rate-limit 100
<<<<<<<< VLAN stack mode
Dell(conf-if-vl-2-stack)#show config
!
interface Vlan 2
no ip address
mtu 1000
vlan-stack compatible
protocol-tunnel rate-limit 100
shutdown
Related
Commands
show protocol-tunnel — displays tunneling information for all VLANs.
show running-config — displays the current configuration.
show protocol-tunnel
Display protocol tunnel information for all or a specified VLAN-Stack VLAN.
Syntax
show protocol-tunnel [vlan vlan-id]
Parameters
vlan vlan-id (OPTIONAL) Enter the keyword vlan then the VLAN ID to
display information for the one VLAN. The range is from 1 to
4094.
Defaults none
Command Modes EXEC
Command History
This guide is platform-specific. For command information about other platforms,
refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.8(0.0) Introduced on the S3048-ON and S4048-ON.
9.7(0.0) Introduced on the S6000-ON.
9.0.2.0 Introduced on the S6000.
1652
Service Provider Bridging