Service Manual

Parameters
source interface Enter one of the following keywords and slot/port
information:
For a 10-Gigabit Ethernet interface, enter the keyword
TenGigabitEthernet then the slot/port[/subport]
information.
For a 40-Gigabit Ethernet interface, enter the keyword
fortyGigE then the slot/port information.
For a VLAN interface enter the keyword VLAN followed
by a number from 1 to 4094.
For a port channel interface, enter the keywords port-
channel
then a number.
range Enter the keyword range to specify the list of interfaces.
any Enter the keyword any to specify all interfaces.
NOTE: This option is applicable only with drop monitor
session.
destination Enter the keyword destination to specify the destination
interface.
For a 10-Gigabit Ethernet interface, enter the keyword
TenGigabitEthernet then the slot/port[/subport]
information.
For a 40-Gigabit Ethernet interface, enter the keyword
fortyGigE then the slot/port information.
For a port channel interface, enter the keywords port-
channel
then a number.
interface Enter one of the following keywords and slot/port
information:
For a 10-Gigabit Ethernet interface, enter the keyword
TenGigabitEthernet then the slot/port[/subport]
information.
For a 40-Gigabit Ethernet interface, enter the keyword
fortyGigE then the slot/port information.
For a VLAN interface, enter the keyword vlan then a
number from 1 to 4094.
For a port channel interface, enter the keywords port-
channel
then a number.
direction {rx | tx |
both}
Enter the keyword direction then one of the packet
directional indicators.
rx: to monitor receiving packets only.
tx: to monitor transmitting packets only.
Port Monitoring