Service Manual

Version Description
8.3.10.0 Replacement command for the S4810 only. Replaces the
enable xfp-power-updates command.
Usage Information To enable polling and to configure the polling frequency, use this command.
enable xfp-power-updates
Enable 10–gigabit small form-factor pluggable (XFP) power updates for SNMP.
Syntax
enable xfp-power-updates interval seconds
Parameters
interval seconds Enter the keyword interval then the polling interval in
seconds. The range is from 120 to 6000 seconds. Default:
300 seconds (5 minutes).
Defaults Disabled
Command Modes CONFIGURATION
Command History
This guide is platform-specific. For command information about other platforms,
refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.8(0.0) Introduced on the S3048-ON and S4048-ON.
9.7(0.0) Introduced on the S6000-ON.
8.3.19.0 Deprecated command for S4820T. Replaced by the enable
optic-info-update interval command to update
information on temperature and power monitoring in the
SNMP MIB.
8.3.11.4 Deprecated command for Z9000. Replaced by the enable
optic-info-update interval command to update
information on temperature and power monitoring in the
SNMP MIB.
8.3.10.0 Deprecated command for the S4810 only. Replaced by the
enable optic-info-update interval command to
update information on temperature and power monitoring
in the SNMP MIB.
8.1.1.0 Introduced on the E-Series ExaScale.
Control and Monitoring
107