Administrator Guide
Version Description
9.13(0.0) Updated to show VLT peer’s local macs.
9.11(0.0) Introduced the static mode on the S4048–ON, S4048T-ON, S6000–ON, S6010–ON,
S6100–ON, and Z9100–ON.
9.10(0.1) Introduced on the S6010-ON and S4048T-ON.
9.10(0.0) Introduced on the S6100–ON.
9.10(0.1P10) Introduced on the Z9100–ON.
9.8(0.0) Introduced on the S4048–ON.
9.7(0.0) Introduced on the S6000-ON.
9.4(0.0) Introduced on the S6000.
Example
DellEMC#show vxlan vxlan-instance 1 unicast-mac-remote
Total Remote Mac Count: 1
VNI MAC TUNNEL
100 00:00:07:00:02:00 (N) 60.1.1.1
Related
Commands
vxlan-instance- Enable VXLAN Instance configuration on the platform.
show vxlan vxlan-instance vtep-vni-map
Displays information on VTEP to VNI mapping for a specific remote VTEP or all remote VTEPs
Syntax
show vxlan vxlan-instance instance ID vtep-vni-map remote-vtep-ip IP-Address
Parameters
instance ID
Enter the VXLAN instance ID. The platform supports only the instance ID 1 in the initial
release.
remote-vtep-ip Enter the keyword remote-vtep-ip followed by the IP address of the remote VTEP.
Command Modes
• EXEC
• EXEC Privilege
Command History
This guide is platform-specific. For command information about other platforms, refer to the relevant Dell EMC
Networking OS Command Line Reference Guide.
Version Description
9.11(0.0) Introduced on the S4048–ON, S4048T-ON, S6000–ON, S6010–ON, S6100–ON, and
Z9100–ON.
Example
DellEMC# show vxlan 1 vtep-vni-map
Remote Vtep IP : 10.10.10.10
VNI profile : Profile1
VNID count : 4
VNID list : 100, 200, 300, 400
Remote Vtep IP : 10.10.10.11
VNI profile : Profile2
VNID count : 3
VNID list : 100, 200, 500